Preparative liquid chromatography system

MK-3200 50DAC preparative high performance liquid chromatography system

Brief Introduction of Equipment
▲MK3000 series preparative chromatography is used in the research and development and production of medicine, food, chemical industry, life sciences, university research institutes, etc., for high-throughput active compound screening, production of peptide drugs, production of raw materials, production of chemical intermediates and other fields use.
▲MK3000 preparative chromatography system is equipped with 200ml/min, 500ml/min, 1000ml/min, 3000ml/min infusion pump system, and different flow rates are available according to customer needs;
▲Used with different volume dynamic axial compression preparative columns, the processing capacity can reach 100g level, MZ series dynamic axial compression columns can load and unload the column by itself, choose different packing according to process requirements, maintain the column pressure at all times, and ensure the chromatographic packing layer Uniformity and compactness keep the column efficiency in the best state at all times, and can ensure that the preparation of large inner diameters maintains the same efficiency as the analytical column.
▲Chromatography software, hierarchical user management, data audit and tracking, in line with GMP requirements;

System Features
▲Solvent transmission double plunger reciprocating pump, double plunger suction, small pulsation; electronic compensation, accurate flow rate;
▲Quick start, stop, and automatic storage of user data;
▲Maximum/minimum pressure is adjustable, high pressure protection, automatic stop when exceeding the set pressure value;
▲Dynamic gradient mixing, solvent mixing is more complete;
▲Signal detection 190-700nm wavelength detection range, wider application range;
▲Independent control, touch screen control, parameter setting, flexible operation; computer control, LAN connection, chromatography software control;
▲Compatible with positive and reverse solvent systems; biocompatible materials can be selected for biological sample purification;
▲The operating status of the instrument (running, error reporting, sleep) can be observed through the panel indicator;